Home > Touchless Bathroom Faucet Installation Instructions for Fontana Commercial Automatic Dark Oil Rubbed Bronze Motion Sensor Faucet

ow to install Fontana Commercial Automatic Dark Oil Rubbed Bronze Touchless Bathroom Faucet | FS1024


Easy step by steps Installation Instructions for Commercial Touchless Sensor Faucet

  • Before you begin, please read the installation instructions below. Observe all local building and safety codes.
  • Unpack and inspect the touchless faucet for any shipping damages for any shipping damages. If you find damages, do not install.
  • Please note all showers must be installed by a professional and certified plumber otherwise warranty might be voided.
sensor Fontana Commercial Automatic Dark Oil Rubbed Bronze Touchless Bathroom Faucet

Sensor Faucet Installations Instructions


Size:



Battery (DC 6V) Only Control Box
Step 1: Step 2: (Hot & Cold Connection)

infrared



Battery (DC 6V) & AC 220V Control Box
Step 3: Step 4:


Step 5: Step 6: Hot & Cold Regulator


Step 7: (Correct way for Hose)




1. Screw the hose into the corresponding screw-hole of the faucet body. Fix the o-ring into the bottom groove of the faucet body.

2. Insert hose, threaded pipe and data cable through the drilled hole of the countertop. Put rubber washer and metal washer onto the threaded pipe, screwing in mounting nut. Adjust the faucet body correctly and tighten the mounting nut with screws.

3. Install the control box to the wall and fix it with screws.

4. Add the rubber washer and screw supply elbow to the control box.

5. Add rubber washers and connect water lines to the hot and cold inlets of the supply elbow. Then connect the hose to the water outlet and insert data cable into the control box and plugin.

6. Make Connections to water supplies. Turn on hot and cold water supplies and flush water lines into a container for one minute. Important: This flushes away any debris that could cause damage to internal parts.

7. Connect waterlines to angle stops. Turn on the angle stops and check for leaks (DO NOT TURN FAUCET ON).

8. Turn the faucet on for 1 minute to flush any debris.


Flexible Connecting Hose

Care must be taken when connecting the flexible connection hose from the power supply box to the spout to ensure it does not bend sharply and kink or twist.
See above for recommended ways to fit the flexible connecting hose.

Important: Failure to follow these guidelines may result in poor performance and damage to the flexible connection hose.


  • Washing Time: 30-second (Default/ Adjustable).
  • Water Pressure: 0.5 - 7.0 KGS/cm, 10 - 125 psi
  • Power Supply: AC110V And DC6V (batteries not included)
  • Battery Life Expectancy: 200,000 cycles
  • Solenoid Valve: 6 Volt magnet latching
  • Working Water Pressure: 1 PSI -100 PSI
  • Supply Inlet Size: 1/2" NPT Male
  • Water Temperature Control: Built-in
  • Sensor Type and Location: Active Infrared, Deck mount
  • Sensor Microprocessor: Digital, Pug, And Play
  • Sensing Range: 2” to 6”
  • Response Time: 0.3 Second
  • Shut-Off Delay Time: 2 Seconds
  • Maximum Running Time: 60 Seconds
  • Particle Filter Size: 50 Mesh
  • Aerator: 2.2 GPM Standard

  • Control Box Installation Instructions


    Step 1: Step 2:
    control box
    Step 3: Step 4:
    Size: 5" x 5"

    AC Cable
    Step 5: Step 6:
    Inserting Batteries
    Your infrared spout is supplied with a back up battery pack (batteries not included). In the event of a power failure the batteries will override the mains power supply to ensure the spout continues to function.


    Before fitting the power supply box into position on the wall/floor, batteries (not included) will need to be fitted.

    1. Remove Power Supply Box Cover
    Remove all four screws in each corner of the power supply box and remove the cover.

    2. Remove Battery Box
    Remove the battery case from the power supply box and remove the screw in the center of the case.

    3. Insert Batteries
    Insert 4 x AA batteries (not included) into the battery box ensuring they are inserted the correct way.
    Note: Only use 1.5V AA (LR6) Alkaline batteries (preferably => 2000mAh for good battery life).

    4. Replace Battery Box
    Replace the battery case cover. Replace and tighten the screw. Insert the battery case back into the power supply box.

    5. Replace Power Supply Cover
    Replace the power supply cover and tighten all 4 screws ensuring they are all fully tightened.


    Installation - Electrical Connections


    1. Position Power Supply Box
    Position the power supply box onto the wall surface below the sink/work surface where it is easily accessible.

    Note: Ensure that the power supply box is fitted the correct way up (see opposite) and that the flexible hose will reach from the underside of the spout to the power supply box.

    Using suitable fixings for the wall type secure the power supply box to the wall.

    2. Connect Power Supply Cable
    Before starting any electrical work ensure the power supply is isolated. Wire the electrical power cable into a switched fused spur off the ring main. The blue wire should be wired to the neutral connection and the brown wire should be connected to the live connection.

    Important: The power supply box must be permanently connected to the fixed wiring of the mains supply using the factory supplied power cable.

    3. Plug In Power Cable
    Plug the power cable into the power supply box.

    4. Connect The Sensor Cable
    Plug the sensor cable from the spout into the power supply box to activate the infrared senor.


    Installation - Water Connections

    Connecting Water Supply
    A blended water supply is required to the inlet of the power supply box. Before connecting the water supply to the power supply box flush through the pipework to ensure removal of debris. Once flushed through turn off the mains water supply and close any isolating valves.

    Inlet Connection
    The inlet connection on the power supply box is a 1/2” BSP male threaded connection. Connect a 1/2” BSP female connector to the inlet connection ensuring a suitable sealing washer is used to create a water tight connection.

    Outlet Connection
    The outlet connection is a standard 1/2” BSP male threaded connection. Connect the flexi hose (supplied) to the outlet connection, ensuring it is tightened fully.



    Fontana Commercial Automatic Dark Oil Rubbed Bronze Touchless Bathroom Faucet


    Fontana's Dark Oil Rubbed Bronze Sensor Faucet is ideal for bathroom & kitchen sinks. The faucet's sensor identifies when an object, like a cup or a hand, is placed beneath the spout. It is our goal to provide the customer with not only excellent products but also a leading lifestyle. This has an elegant design and elevates the appeal of your decor made from the highest quality and for great tastes. It comes super seal technology inside, capable of delivering superior performance with solid construction for long durability that will upgrade your bathroom with a modern and cool look for a long period of time. Give your bathroom an elegant glance with these bathroom fixtures. This is one of the trendiest finishes across decor styles in the bathroom. When it comes to new bathroom upgrades, FontanaShowers is offering shape, finishes, and styles that you've looking for. This Sensor faucet is built for extremely reliable infrared activation and vandal resistance in high traffic washrooms.

    Features:

    • Brand Name: Fontana Dark Oil Rubbed Bronze Touchless Bathroom Faucet
    • Model Number: FS1024
    • Washing Time: 30-second (Default/ Adjustable).
    • Water Pressure: 0.5 - 7.0 KGS/cm, 10 - 125 psi
    • Material: Solid Brass Construction
    • Finish: Dark Oil Rubbed Bronze
    • Power Supply: AC110V And DC6V (batteries not included)
    • Sensor Faucet Applications: Residential & Commercial use.
    • Battery Life Expectancy: 200,000 cycles
    • Solenoid Valve: 6 Volt magnet latching
    • Working Water Pressure: 1 PSI -100 PSI
    • Supply Inlet Size: 1/2” NPT Male
    • Water Temperature Control: Built-in
    • Pop-Up Drain Rod: N/A
    • Sensor Type and Location: Active Infrared, Deck mount
    • Sensor Microprocessor: Digital, Pug, And Play
    • Sensing Range: 2” to 6”
    • Response Time: 0.3 Second
    • Shut-Off Delay Time: 2 Seconds
    • Maximum Running Time: 60 Seconds
    • Particle Filter Size: 50 Mesh
    • Aerator: 2.2 GPM Standard
    • Usage: Ideal for commercial use applications in public restrooms, restaurants, office building, public facilities, hospitals. Fits all standard US plumbing.
    Fontana Commercial Automatic Dark Oil Rubbed Bronze Touchless Bathroom Faucet


    Shower & Faucet Installation Instructions