Home > Touchless Bathroom Faucet Installation Instructions for Solo Commercial Automatic Touchless Sensor Faucet

How to install Solo Commercial Automatic Touchless Sensor Faucet | FS-509N


Easy step by steps Installation Instructions for Sensor Faucet Visit Product Page

  • Before you begin, please read the installation instructions below. Observe all local building and safety codes.
  • Unpack and inspect the products for any shipping damages. If you find damages, do not install.
  • Please note all products must be installed by a professional and certified plumber otherwise warranty might be voided.
sensor Solo Commercial Automatic Touchless Sensor Faucet

Sensor Faucet Installations Instructions


Size Hole Size Chart

sensor




  • Type
    :
    Ceramic Plate Spool
  • Style : Contemporary
  • Surface Treatment : Polished Chrome
  • Valve Core Material : Ceramic
  • Feature : Waterfall Swivel Spout
  • Installation Type : Deck Mounted
  • Installation Holes: Single Hole
  • Water Pressure : 0.1-0.7Mpa
  • Cold & Hot Water : Yes


Deck Mount Installation

Battery (DC 6V) Only Control Box
Step 1: Step 2: (Hot & Cold Connection)

sensor



Battery (DC 6V) & AC 220V Control Box
Step 3: Step 4:


Flush Debris from waterpipes Hot & Cold Regulator


Control Box Correct way for Hose




1. Screw the hose into the corresponding screw-hole of the faucet body. Fix the o-ring into the bottom groove of the faucet body.
2. Insert hose, threaded pipe and data cable through the drilled hole of the countertop. Put rubber washer and metal washer onto the threaded pipe, screwing in mounting nut. Adjust the faucet body correctly and tighten the mounting nut with screws.
3. Install the control box to the faucet.
4. Then connect the battery cable to the control box.
5. Make Connections to water supplies. Turn on the water supply and flush water lines into a container for one minute.
Important: This flushes away any debris that could cause damage to internal parts.

6. Connect waterlines to angle stops. Turn on the angle stops and check for leaks (DO NOT TURN FAUCET ON).
7. Turn the faucet on for 1 minute to flush any debris.


Flexible Connecting Hose

Care must be taken when connecting the flexible connection hose from the power supply box to the spout to ensure it does not bend sharply and kink or twist.
See above for recommended ways to fit the flexible connecting hose.

Important: Failure to follow these guidelines may result in poor performance and damage to the flexible connection hose.



Control Box Installation Instructions

Step 1: Step 2:
control box
Step 3: Step 4:
5" size


Step 5: Step 6:

Step 7:
Control Box Installation
1. Remove the four screws from the control box. Remove the control box cover. Remove the battery box from the control box, and gently remove the screw from the battery box cover. Install AA batteries in the orientation shown. Note: Use only alkaline AA batteries. Re-install the battery box cover, matching the alignment arrows together. Set the battery box back into the control box, and re-install the control box cover using the previously removed screws.

2. Choose a location under the sink basin to mount the control box, such that the sensor cable, flexible hose, and incoming water supply all connect to the control box. Under the sink basin, drill a hole minimum 3/4” to fit the sensor cable and flexible hose from the spout. Feed the sensor cable and flexible hose through the hole.

3. Mount the control box to the wall in the orientation shown. Drill four 1/8" (3mm) holes, and push drywall anchors into each hole. Secure the control box to the wall with the drywall screws.

4. Connect the incoming water supply line to the control box, at the connection marked Inlet.

5. Thread on the swivel nut to the hose by hand. Tighten with a wrench.

6. Connect the faucet hose to the control box, at the connection marked Outlet.

7. Slide sensor cable connector over the sensor cable connector on the control box and tighten by hand.
Note: Prior to connecting the sensor cable to the control box, open the water supply stop valve and ensure the sink basin is completely clean and clear of objects, or the sensor will not correctly calibrate. Please wait approximately 60 seconds after connecting the sensor cable for sensor calibration to complete and to begin using the faucet.


Inserting Batteries
Your infrared spout is supplied with a back up battery pack (batteries not included). In the event of a power failure the batteries will override the mains power supply to ensure the spout continues to function.


Before fitting the power supply box into position on the wall/floor, batteries (not included) will need to be fitted.

1. Remove Power Supply Box Cover - Remove all four screws in each corner of the power supply box and remove the cover.
2. Remove Battery Box - Remove the battery case from the power supply box and remove the screw in the center of the case.
3. Insert Batteries - Insert 4 x AA batteries (not included) into the battery box ensuring they are inserted the correct way.
4. Replace Battery Box - Replace the battery case cover. Replace and tighten the screw. Insert the battery case back into the power supply box.
5. Replace Power Supply Cover - Replace the power supply cover and tighten all 4 screws ensuring they are all fully tightened.


Electrical Connections


1. Position Power Supply Box - Position the power supply box onto the wall surface below the sink/work surface where it is easily accessible.
Note: Ensure that the power supply box is fitted the correct way up and that the

Shower & Faucet Installation Instructions